header 01 prodotti header 03 header 04
homedovecontattiheader 05
header 06
     
 
 
AXIAL FANS
AX-SA SERIES
 
AX-SA Series
MA Series
 
AX-SA
Detail
 
AX-SA
Detail
 
 
 
Clicca per ingrandire Download Brochure - PDF fileDownload Brochure - ZIP file

alert
Please note:

All images, graphics
and photographs are
copyrighted by Coprel S.r.l.
Technical specifications:
axial fan;
single phase, 2-shaded poles, impedance protected motor, built according to the "CE" mark requirements, in compliance with EN 60335-1 standard, with self-aligning and self lubricating sleeve bearings with big oil reservoir;
motor with minimum 130 "B" insulation class;
suitable for continuous operation in ambient temperature from -10°C to +50°C;
electrical connection by 6.3,3x0,8mm, radial or axial, male faston-type connectors, directly fixed on coil (see table 1);
fan blade made of nylon reinforced with fiber glass or aluminium (see Table 1);
motor support bracket made of galvanized metal sheet.
 
On request:
version with IMQ - CSV approved motor;
fans blades of various diameters and inclinations;
motor with different powers and insulation classes: 155 “F” - 180 “H”;
protection against dust and/or humidity;
end-shields with “IP50” protection class;
motor coil winding with IP55 protection;
supply voltage from 12V to 400V 50/60Hz;
double speed and/or dual voltage version;
electrical connection by means of different cable lengths;
thermal protector or thermal fuse;
without the support bracket;
spacers of various lengths and/or protruding screws for fan wall mounting;
built in compliance with UL-CSA standards;
version with double shield ball bearings (ZZ);
motor cover made of black nylon reinforced with fibreglass;
SA type bracket for use with fan blades 200 mm and 230 mm diameter.
 
top

OUR TECHNICAL AND COMMERCIAL OFFICE
CAN ADVISE YOU ON THE VERSION THAT MOST SUITS YOUR APPLICATION NEEDS

top

Product Identification Code
(point your mouse on the item to view details)
 
LF a richiestaa richiestaa richiesta protezione termica posizione faston a richiesta a richiesta posizione faston protezione termica RG
* Impregnated versions:
IV Version: impregnated coil through dip-coating using epoxy transparent paint (standard stator coil dip-coating process).
PRN version: coil coated with black epoxy resin, the coil is protected by a clearly visible layer of resin.
IM Version: impregnated coil through dip-coating using transparent epoxy paint with silicone applied on contacts at the end of winding, three-pole wire and coil covered by a nylon cap. The coil is not buried in the resin but visible; caution should be paid when mounting the motor so that the cap open part faces downward to prevent its filling up with condensate.
INC Version: coil with IP55 protection, the coil is completely buried into the epoxy resin.
top

Faston position (table 1) 
posizione
top

Fan blade action
ventola
top

AX dimensions
Copyright © Coprel s.a.s.
The dimensions are in millimeters
top

AX versions
 
top

SA dimensions
dimensioni
The dimensions are in millimeters
top

SA versions
 
top

All Coprel motors and fans are manufactured in our factory in Pieve Emanuele. Dimensions and specifications data can change. Changes can be made any time, as we may deem feet.

 

 
footer 08
protezione termica